The eTOPxxC series, eTOP300 series and eTOP04C operator panels have an integrated USB port that can be used to programmer the device trough an USB flash drive.
Using Designer programming software the application and the firmware files to be used into the unit can be downloaded into the USB flash drive, it is also possible to upload an application from the USB flash drive.
Note: the USB flash drive must be FAT or FAT16 formatted to be compatible with Designer series operator panels, the maximum size supported by these formats is 2GB.
Programming the panel through the USB flash drive
The download operation trough an USB flash drive is performed in two steps: the download of the application into the USB flash drive and then copy of the USB flash drive content into the operator panel.
Download
Note: the Firmware files should not be downloaded into the USB flash drive unless this is necessary. The download is necessary in case the operator panel internal memory has been formatted, in this case make sure the Firmware files version is the same of the Firmware already installed into the operator panel. The download of the Firmware files is needed if an upgrade of Firmware is required on panel, in this case please contact our Technical Support department at techsupp@exorint.it to verify the correct Firmware version to be used with your unit.
Copy of the USB flash drive content into the operator panel.
Note: the eTOP04C panel model uses a simplified textual Memory Setup menu, the copy procedure in this case is the following: from the Memory Setup menu select the Copy voice using the Arrow keys to move the cursor and confirm the selection with Enter button. Select then Project USB -> Panel Memory voice, confirm with Enter and then start the copy with Up Arrow button as reported also in page.
Read the application from the USB flash drive
As per the programming of the panel the operation is composed by two separate steps: the copy of the Panel internal memory content into the USB flash drive and then the Upload of the USB flash drive content in designer.
Copy the content of the Panel internal memory into the USB flash memory
Note: the eTOP04C panel model uses a simplified textual Memory Setup menu, the copy procedure in this case is the following: from the Memory Setup menu select the Copy voice using the Arrow keys to move the cursor and confirm the selection with Enter button. Select then Project Panel Memory -> USB voice, confirm with Enter and then start the copy with Up Arrow button as reported also in page.
Upload
Designer 6.07 or newer
eTOPxxC serie operator panels (FW70), eTOP300 serie operator panels, eTOP04C